Air Conditioner — Relays: Removal / Installation, Inspection
G-70prose procedureRELAYS
Removal / Installation
Relays — Removal / Installation
- 1Remove the relays from the relay bracket.

- 2Disconnect the relay connector and remove the relays.
- 3Install in the reverse order of removal. Lower the relay boots after connecting the relay connector.
Inspection
Relays — Inspection
- 1Remove the relays.
- 2Check for continuity between the relay terminals.

B+: Battery positive voltage
Relay Continuity
—
Connection GND—
Terminal AO
Terminal BO
Terminal C
Terminal D
A
Connection GNDB
Terminal A
Terminal B
Terminal CO
Terminal DO
O–O : Continuity
3. If not as specified, replace the relay.