TROUBLESHOOTING - Intake air mode does not change (continued)
G-31flowchartStep 3
- 1Turn the ignition switch to OFF.
- 2Disconnect the air intake actuator connector.
- 3Check for continuity between the following terminal wires of the air intake actuator connector and ground while operating the REC/FRESH switch.

Step 3
(L/W)
SwitchREC
ContinuityYes
ActionCheck (L/R) wire
(L/W)
SwitchREC
ContinuityNo
ActionGo to Step 4
(L/R)
SwitchFRESH
ContinuityYes
ActionCheck air intake actuator (Refer to page G-42)
(L/R)
SwitchFRESH
ContinuityNo
ActionGo to Step 4
Step 4
- 1Verify that the ignition switch is at OFF.
- 2Disconnect the heater control unit connectors.
- 3Check for continuity between the following terminal wires of the air intake actuator and heater control unit connectors.

Step 4
(L/R)
ContinuityYes
ActionCheck for continuity at (L/W)-(L) wire
(L/R)
ContinuityNo
ActionRepair wiring harness (Heater control unit - Air intake actuator)
(L/W) (L)
ContinuityYes
ActionCheck heater control unit (Refer to page G-43)
(L/W) (L)
ContinuityNo
ActionRepair wiring harness (Heater control unit - Air intake actuator)