FLOWCHARTS — Flowchart No. 1 (continued): Steps 2–5
G-13flowchartTROUBLESHOOTING
Step 2
Check the REAR WIPER 10A fuse in the fuse block.
Step 2 — Check REAR WIPER 10A fuse
1
REAR WIPER 10A fuse condition?
Burnt
Replace fuse after checking and repairing wiring harness
OK
2
Go to Step 3
Step 3
- 1Turn the ignition switch to ON.
- 2Set the fan switch to the fourth position.
- 3Measure the voltage at the following terminal wires of the blower relay connector.B+: Battery positive voltage

Step 3 — Blower relay connector voltage
(GY)
VoltageB+
ActionMeasure voltage at (L/W) wire
(GY)
VoltageOther
ActionRepair wiring harness (REAR WIPER 10A fuse—Blower relay)
(L/W)
VoltageB+
ActionMeasure voltage at (B) wire
(L/W)
VoltageOther
ActionRepair wiring harness (Circuit breaker—Blower relay)
(B)
VoltageB+
ActionRepair wiring harness (Blower relay—GND)
(B)
VoltageOther
ActionMeasure voltage at (L) wire
(L)
VoltageB+
ActionGo to Step 4
(L)
VoltageOther
ActionReplace blower relay (Refer to page G-42)
Step 4
- 1Verify that the ignition switch is at ON and that the fan switch is in the fourth position.
- 2Measure the voltage at the following terminal wires of the blower motor connector.B+: Battery positive voltage

Step 4 — Blower motor connector voltage
(L)
VoltageB+
ActionMeasure voltage at (L/W) wire
(L)
VoltageOther
ActionRepair wiring harness (Blower relay—Blower motor)
(L/W)
Voltage0V
ActionReplace blower motor (Refer to page G-41)
(L/W)
VoltageOther
ActionGo to Step 5
Step 5
Measure the voltage at the (L/W) terminal wire of the resistor connector.
Step 5 — Resistor connector voltage
0V
ActionRepair wiring harness (Blower motor—Resistor)
Other
ActionGo to Step 6