Mazda MX-3 silhouetteMX-3

IGNITION SYSTEM

G-29parts diagram

Distributor R/I shown for both K8 DOHC (with resonance duct, firing order 6-4-5/1-2-3 wait... cap terminal positions) and B6 DOHC. Resonance duct (callout 1) applies to K8 only. O-ring must be replaced on reinstallation.

Removal / Installation

  1. 1
    Disconnect the negative battery cable.
  2. 2
    Remove in the order shown in the figure.
    K8 DOHC distributor removal/installation exploded view in the engine bay. Numbered callouts: 1 resonance duct (K8), 2 high-tension lead, 3 connector, 4 distributor. An O-RING REPLACE note marks the distributor O-ring. Tightening torque 19—25 {1.9—2.6, 14—18} N·m {kgf·m, ft·lbf} for the distributor mounting bolt. An inset (lower left) shows FIRING ORDER AND POSITION on the distributor cap: terminals 6,4,5 top and 1,2,3 bottom.
  3. 3
    Install in the reverse order of removal.
  4. 4
    Adjust the ignition timing. (Refer to page G-23.)

K8 DOHC

B6 DOHC

Parts DiagramFig. fig1
#Part NameNotes
1Resonance duct (K8)K8 DOHC only
2High-tension leadInspection ... page G-24
3Connector
4DistributorDisassembly / Assembly ... page G-30; Inspection ... page G-31
Tightening torque (distributor)K8 and B6 DOHC
19 - 25N·m

Search Manual