FLOWCHARTS — Flowchart No. 2: Blower motor does not operate with fan switch at specific position
G-15flowchartTROUBLESHOOTING
Flowchart No. 2
Flowchart No.
Value2
Symptom
ValueBlower motor does not operate with fan switch at specific position
Related components
ValueResistor, fan switch, wiring harness
Step 1
- 1Turn the ignition switch to ON.
- 2Verify that the fan switch is off.
- 3Measure the voltage at the following terminal wires of the resistor connector.B+: Battery positive voltage

Step 1 — Resistor connector voltage
(L/W)
VoltageB+
ActionMeasure voltage at (L) wire
(L/W)
VoltageOther
ActionReplace resistor (Refer to page G-41)
(L)
VoltageB+
ActionMeasure voltage at (L/R) wire
(L)
VoltageOther
ActionReplace resistor (Refer to page G-41)
(L/R)
VoltageB+
ActionMeasure voltage at (L/Y) wire
(L/R)
VoltageOther
ActionReplace resistor (Refer to page G-41)
(L/Y)
VoltageB+
ActionGo to Step 2
(L/Y)
VoltageOther
ActionReplace resistor (Refer to page G-41)