Mazda MX-3 silhouetteMX-3

FLOWCHARTS — Flowchart No. 3: Magnetic clutch and condenser fan do not operate

G-17flowchart

AD FAN fuse is 40A on K8 (V6), 20A on B6 (I4). Bracketed [ ] values throughout refer to the B6 engine. K8 uses condenser fan relays No.1 and No.2; B6 uses a single condenser fan relay.

TROUBLESHOOTING

Flowchart No. 3

Flowchart No.
Value3
Symptom
ValueMagnetic clutch and condenser fan do not operate
Related components
ValueFuse, A/C relay, ECM, heater control unit, thermoswitch, refrigerant pressure switch

System Operation

Signals from the fan switch and A/C switch are sent to the ECM.
The thermoswitch detects the evaporator temperature and opens or closes the circuit to keep the evaporator temperature at a certain level to protect against freezing.
To help liquefy the refrigerant, the condenser fan rotates and sends airflow to the condenser when the A/C compressor is on.

Step 1

  1. 1
    Check the following fuses.
    Illustration of the fuse block with an arrow pointing to the REAR WIPER 10A fuse.
  2. 2
    If the fuses are OK, go to Step 2.
  3. 3
    If a fuse is burnt, check for a short circuit in the wiring harness before replacing the fuse.

Step 1 — Fuses to check

REAR WIPER
Amperage (A)10
LocationFuse block
AD FAN
Amperage (A)40 [20]
LocationMain fuse block No.2 [Main fuse block No.1]

Search Manual

Search pages, specs, and procedures