CONTROL SYSTEM — ECM Terminal Voltage Inspection (Incorrect Voltage / Possible Cause)
F2-147spec tableReferences diagnostic trouble code troubleshooting (codes 02, 03, 04, 05, 10, 16, 26, 41, 46).
NOTE
B+: Battery positive voltage
ECM Terminal — Incorrect Voltage / Possible Cause
2H
Incorrect voltage—
Possible cause—
2I
Incorrect voltageAlways approx. 0V
Possible causeShort circuit in wiring from ECM
2J
Incorrect voltageAlways approx. 0V or approx. 5V
Possible causeRefer to code No. 16 Troubleshooting (Refer to page F2-85)
2K
Incorrect voltageAlways 0V
Possible causeRefer to code No. 10 Troubleshooting (Refer to page F2-82)
2L
Incorrect voltageAlways 0V (DRL system OK)
Possible causeOpen or short circuit in wiring from DRL relay to ECM terminal 2L
2M
Incorrect voltageAlways 0V or B+
Possible causeRefer to code No. 05 Troubleshooting (Refer to page F2-79)
2N
Incorrect voltage—
Possible cause—
2O
Incorrect voltageAlways 0V or approx. 5V
Possible causeRefer to code No. 26 Troubleshooting (Refer to page F2-88)
2P
Incorrect voltageAlways below 2V or B+
Possible causeOpen or short circuit in wiring from coolant fan relay to ECM terminal 2P; ECM malfunction
3A
Incorrect voltageAbove 0V
Possible causePoor connection at ground terminal; Open circuit in wiring from ECM
3B
Incorrect voltageAbove 0V
Possible causePoor connection at ground terminal; Open circuit in wiring from ECM
3C
Incorrect voltageAbove 0V
Possible causePoor connection at ground terminal; Open circuit in wiring from ECM
3D
Incorrect voltageAbove 0V
Possible causePoor connection at ground terminal; Open circuit in wiring from ECM
3E
Incorrect voltageAlways approx. 0V or approx. 5V
Possible causeRefer to code No. 04 Troubleshooting (Refer to page F2-78)
3F
Incorrect voltageAbove 0V
Possible causePoor connection at ground terminal; Open circuit in wiring from ECM
3G
Incorrect voltageAlways approx. 0V or approx. 5V
Possible causeRefer to code No. 03 Troubleshooting (Refer to page F2-77)
3H
Incorrect voltage0V
Possible causeRefer to code No. 02 Troubleshooting (Refer to page F2-76)
3I
Incorrect voltageAlways approx. 0V or B+
Possible causeRefer to code No. 41 Troubleshooting (Refer to page F2-91)
3J
Incorrect voltageAlways approx. 0V or B+
Possible causeRefer to code No. 46 Troubleshooting (Refer to page F2-91)
3K
Incorrect voltage—
Possible cause—
3L
Incorrect voltageAlways below 1.0V or B+
Possible causeOpen or short circuit in wiring from coolant fan relay to ECM terminal 3L; ECM malfunction
3M
Incorrect voltageAlways below 1.0V or B+
Possible causeRefer to code No. 26 Troubleshooting (Refer to page F2-88)
3N
Incorrect voltageAlways below 2.0V
Possible causeOpen or short circuit in wiring from condenser fan relay to ECM terminal 3N; ECM malfunction