Condenser Fan System — K8 DOHC (Circuit G-2)
Z-82wiring diagramK8 DOHC engine condenser fan system, three-relay two-speed (series/parallel) configuration. (( ))...Canada.
Condenser Fan System — K8 DOHC (G-2)
NOTE
Legend: (( ))...Canada. This circuit applies to the K8 DOHC engine and uses three condenser fan relays (No.1/No.2/No.3) for two-speed series/parallel fan operation.
Condenser Fan System Circuit (G-2, K8 DOHC)
Components (14)
Battery100A MAIN fuse40A AD FAN fuse (X-02)10A ENGINE fuse (JB-04/JB-05)10A REAR WIPER fuse (JB-06/JB-07)Ignition switchA/C relayCondenser fan relay No.1Condenser fan relay No.2Condenser fan relay No.3Magnetic clutchCondenser fan motorECM (Section B-2c, pins 55/58/59)Ground (G)
Connections (16)
Battery
Battery:+100A MAIN fuseBlack
40A AD FAN fuse (X-02)
40A AD FAN fuse (X-02)A/C relayBlue with Yellow stripe
40A AD FAN fuse (X-02)Condenser fan relay No.1Blue with Yellow stripe
40A AD FAN fuse (X-02)Condenser fan relay No.2Blue with Yellow stripe
Ignition switch
Ignition switchA/C relayGray
Ignition switchCondenser fan relay No.2Gray
Ignition switchCondenser fan relay No.3Red with Yellow stripe
A/C relay
A/C relayMagnetic clutchRed
A/C relayECM (Section B-2c, pins 55/58/59):55Blue with Black stripe
Condenser fan relay No.1
Condenser fan relay No.1ECM (Section B-2c, pins 55/58/59):59Pink with Black stripe
Condenser fan relay No.1Condenser fan motorBlue with Red stripe
Condenser fan relay No.2
Condenser fan relay No.2ECM (Section B-2c, pins 55/58/59):58Yellow with Black stripe
Condenser fan relay No.2Condenser fan motorBlue
Condenser fan relay No.3
Condenser fan relay No.3Condenser fan motorBlue with Green stripe
Condenser fan motor
Condenser fan motorGround (G):2Black
Magnetic clutch
Magnetic clutchGround (G)Black
Connector terminal layouts
G2-01
NameA/C Relay (AC)
TerminalsRow 1: L/Y, GY | Row 2: R, L/B
G2-02
NameCondenser Fan Relay No.1 (AC)
TerminalsRow 1: L/Y, B/W | Row 2: L/R, Y/B
G2-03
NameCondenser Fan Relay No.2 (AC)
TerminalsRow 1: L/Y, GY | Row 2: L, R/Y
G2-04
NameCondenser Fan (AC)
TerminalsRow 1: L, L/R | Row 2: L/G, B
G2-05
NameMagnetic Clutch (AC)
TerminalsR
G2-06
NameCondenser Fan Relay No.3 (AC)
TerminalsRow 1: L/G, GY | Row 2: B, R/Y
See also
Section B-2c