TECHNICAL DATA — COOLING SYSTEM (B6 cont.) / E2. COOLING SYSTEM (K8)
TD-11spec tableFirst two tables continue E1 cooling system for B6 DOHC (1.6L I4); E2 is for K8 DOHC (1.8L V6).
Cooling system — B6 DOHC (coolant fan, water thermoswitch, coolant)
Coolant fan — Type
Sub-item
B6 DOHCElectric
Coolant fan — Number of blades
Sub-item
B6 DOHC4
Coolant fan — Outer diameter mm {in}
Sub-item
B6 DOHC300 {11.8}
Coolant fan — Capacity W-V
Sub-item
B6 DOHC80–12
Coolant fan — Current A
Sub-item
B6 DOHC5.6–7.6
Water thermoswitch — OFF/ON °C {°F}
Sub-item
B6 DOHC97 {207}
Coolant — Capacity L {US qt, Imp qt}
Sub-item
B6 DOHC6.0 {6.3, 5.3}
B6 DOHC antifreeze solution
Above -16°C {3°F}
Volume percentage % — Water65
Volume percentage % — Coolant35
Specific gravity at 20°C {68°F}1.054
Above -26°C {-15°F}
Volume percentage % — Water55
Volume percentage % — Coolant45
Specific gravity at 20°C {68°F}1.066
Above -40°C {-40°F}
Volume percentage % — Water45
Volume percentage % — Coolant55
Specific gravity at 20°C {68°F}1.078
E2. COOLING SYSTEM (K8)
Cooling system — K8 DOHC
Cooling method
K8 DOHCWater-cooled, forced circulation
Water pump — Type
K8 DOHCCentrifugal, V-ribbed belt-driven
Water pump — Impeller diameter mm {in}
K8 DOHC60 {2.36}
Water pump — Number of impeller blades
K8 DOHC6
Water pump — Speed ratio
K8 DOHC1 : 1.05
Water pump — Water seal type
K8 DOHCUnified mechanical seal
Thermostat — Type
K8 DOHCWax, bottom-bypass
Thermostat — Opening temperature °C {°F}
K8 DOHC80–84 {176–183}
Thermostat — Full-open temperature °C {°F}
K8 DOHC95 {203}
Thermostat — Full-open lift mm {in}
K8 DOHC8.5 {0.33} min.
Radiator — Type
K8 DOHCCorrugated fin
Radiator — Cap valve opening pressure kPa {kgf/cm², psi}
K8 DOHC74–102 {0.75–1.05, 10.7–14.9}
Radiator — Cooling circuit checking pressure kPa {kgf/cm², psi}
K8 DOHC103 {1.05, 15}